2. Locate the timing alignment mark (1) on the front of the actuator.

3. Engage the actuator timing gear teeth with the secondary timing chain ensuring that the actuator alignment mark (5) corresponds with the paint

mark created on the chain link.

4. Slide the actuator over the camshaft alignment pin and install the actuator onto the camshaft.
5. Install the right intake camshaft position actuator oil control valve.

Camshaft Position (CMP) Actuator Housing Replacement - Left

Camshaft Position (CMP) Actuator Housing Replacement - Left 
Removal Procedure

1. Remove the fuel injector sight shield.