METAL COLLAR QUICK CONNECT FITTING SERVICE

TOOLS REQUIRED

-

J 37088-A Fuel Line Disconnect Tool Set

-

J 44581 Fuel Line Disconnect Tool

REMOVAL PROCEDURE

1. Relieve the fuel system pressure. Refer to Fuel Pressure Relief.
2. Remove the retainer from the quick-connect fitting.
3. Blow dirt out of the fitting using compressed air.

CAUTION:  Wear safety glasses when using compressed air, as flying dirt particles may cause eye injury.

4. Choose the correct tool for the size and access of the fitting: J 37088-A or J 44581. Insert the tool into the female connector, then push inward to

release the locking tabs.

5. Pull the connection apart.
6. Using a clean shop towel, wipe off the male pipe end.

NOTE:  If necessary, remove rust or burrs from the fuel pipes with an emery cloth. Use a radial motion with the fuel pipe end in order to prevent
damage to the O-ring sealing surface. Use a clean shop towel in order to wipe off the male tube ends. Inspect all the connections for dirt and burrs.
Clean or replace the components and assemblies as required.

7. Inspect both ends of the fitting for dirt and burrs. Clean or replace the components as required.

INSTALLATION PROCEDURE