STS RWD V8-4.6L VIN A (2006)
Alternator: Service and Repair
Generator Replacement
GENERATOR REPLACEMENT
REMOVAL PROCEDURE
1. Disconnect the battery negative cable.
2. Remove the generator drive belt.
3. Remove the upper generator mounting bolts (1, 3).
4. Raise and support the vehicle. Refer to Vehicle Lifting.
5. Remove the front air deflector.
6. Cut the tie strap securing the wiring harness to the generator.
7. Remove the lower generator mounting bolt.
8. Lift the generator off of the mounting bracket in order to gain access to the connector and the generator output BAT terminal nut.
9. Disconnect the wire harness electrical connector from the generator.
10. Reposition the protective boot from the generator output battery terminal for access.
11. Remove the generator output battery terminal nut and disconnect the battery positive lead from the generator.
12. Remove the generator from the vehicle.
INSTALLATION PROCEDURE
1. Position the generator near the installed position.