chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Blower Motor Switch > < Blower Motor Resistor Assembly Replacement (With RPO Code YG6)|Page 7020
Page 1
background image

Blower Motor Resistor: Service and Repair
Blower Motor Resistor Replacement - Heater Auxiliary

BLOWER MOTOR RESISTOR REPLACEMENT -  HEATER AUXILIARY

REMOVAL PROCEDURE

1. Remove the left body side trim panel. 
2. Remove the electrical connector.
3. Remove the screws from the auxiliary heater blower motor resistor assembly.
4. Remove the auxiliary heater blower motor resistor assembly (1) from the heater case.

INSTALLATION PROCEDURE

1. Install the auxiliary heater blower motor resistor assembly (1) into the heater case.
2. Install the auxiliary heater blower motor resistor assembly screws.

NOTE:  Refer to Fastener Notice in Service Precautions.

Tighten
Tighten the screws to 2 N.m (18 lb in).

3. Install the electrical connector.
4. Install the left body side rear trim panel. 

Blower Motor Switch > < Blower Motor Resistor Assembly Replacement (With RPO Code YG6)|Page 7020