chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 4057 > < Diagram Information and Instructions|Page 4055
Page 7
background image

-

If fuse does not blow, refer to next step.

4. Close each connector or switch until the fuse blows in order to find which circuit has the short. Connect test lamp or meter at the connector to the

suspect circuit (disconnected) rather than at the fuse terminals.

 

Testing For Voltage

Voltage Check

1. Connect one lead of a test light to a known good ground. When using a Digital Voltmeter (DVM), be sure the voltmeter's negative lead is

connected to ground.

2. Connect the other lead of the test light or voltmeter to a selected test point (connector or terminal).
3. If the test light illuminates, there is voltage present. When using a DVM, note the voltage reading.

Testing For Voltage Drop

Voltage Drop Test

This test checks for voltage being lost along a wire, or through a connection or switch.

1. Connect the positive lead of a Digital Voltmeter (DVM) to the end of the wire (or to one side of the connection or switch) which is closer to the

Battery.

2. Connect the negative lead to the other end of the wire (or the other side of the connection or switch).
3. Operate the circuit.
4. The DVM will show the difference in voltage between the two points.

Test Light/Digital Voltmeter

Diagram Information and Instructions|Page 4057 > < Diagram Information and Instructions|Page 4055