Avalanche 2500 4WD V8-8.1L VIN G (2003)
4. Remove the ECT sensor.
INSTALLATION PROCEDURE
1. If installing the old sensor, coat the threads with sealant GM P/N United States 12346004 (Canadian P/N 10953480) or equivalent.
NOTE: Refer to Fastener Notice in Service Precautions.
2. Install the ECT sensor.
Tighten
Tighten the sensor to 20 N.m (15 lb ft).