2. Install the mode actuator mounting screw to the HVAC module.

NOTE:  Refer to Fastener Notice in Service Precautions.

Tighten
Tighten the screw to 1.6 N.m (14 lb in).

3. Connect the electrical connection at the mode actuator (10).

4. Install the floor air outlet duct extension (1) to the floor air duct (2).

Recirculation Actuator Replacement (Delphi)

REMOVAL PROCEDURE

1. Remove the air distribution duct.