chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Positive Crankcase Ventilation > < Exhaust Gas Recirculation (EGR) Valve|Page 9956
Page 1
background image

EGR Valve: Service and Repair
Exhaust Gas Recirculation (EGR) Valve Bracket

REMOVAL PROCEDURE

1. Remove the exhaust gas recirculation (EGR) valve.
2. Remove the EGR Pipe.
3. Remove the EGR valve adapter bracket nuts.
4. Remove the EGR valve adapter bracket.
5. Remove the EGR adapter gasket.
6. Clean the intake manifold.

INSTALLATION PROCEDURE

1. Install a NEW EGR gasket onto the intake manifold.
2. Install the EGR valve adapter bracket.

NOTE:  Refer to Fastener Notice in Service Precautions.

3. Install the EGR valve adapter bracket nuts.

Tighten
Tighten the nuts to 22 N.m (16 lb ft).

4. Install the EGR pipe.
5. Install the EGR valve.

Positive Crankcase Ventilation > < Exhaust Gas Recirculation (EGR) Valve|Page 9956