with pigtail. The inflatable restraint steering wheel module coil is an example of a pigtail component.

SIR/SRS Wire Repair

Note:  Refer to Wiring Repairs in the service information connector end views or the vehicle schematics in order to determine the correct wire size for
the circuit you are repairing. You must obtain this information in order to ensure circuit integrity.

If any wire except the pigtail is damaged, repair the wire by splicing in a new section of wire of the same gauge size (0.5 mm, 0.8 mm, 1.0 mm etc.). Use
the DuraSeal splice sleeves and EL-38125-10 - tool. For wiring repair, refer to Splicing Copper Wire Using Splice Sleeves   See: Testing and
Inspection/Component Tests and General Diagnostics/Wiring Repairs/Splicing Copper Wire Using Splice Sleeves.

For connector position assurance (CPA), refer to Connector Position Assurance Locks   See: Testing and Inspection/Component Tests and General
Diagnostics/Connector Repairs/Connector Position Assurance Locks.

For terminal position assurance (TPA), refer to Terminal Position Assurance Locks   See: Testing and Inspection/Component Tests and General
Diagnostics/Connector Repairs/Terminal Position Assurance Locks.

Splicing Copper Wire Using Splice Sleeves

Splicing Copper Wire Using Splice Sleeves

Special Tools

*

EL-38125-10 - Splice Sleeve Crimping Tool

*

J-38125-5A - Ultra Torch Special Tool

*

J-38125-8 - Splice Sleeve Crimping Tool

*

DuraSeal splice sleeves, in order to repair the SIR/SRS wiring

For equivalent regional tools, refer to Special Tools   See: Power and Ground Distribution/Tools and Equipment.

Danger: In order to reduce the risk of personal injury, loss of high voltage isolation to ground and higher system impedance, do not attempt to
repair any HV wiring, connector, or terminal that is damaged. High voltage coaxial type cables are not repairable. Never attempt to repair a
coaxial type cable. The entire cable/harness or component must be replaced. In order to maintain system integrity and personal safety, never
attempt to repair any high voltage wiring, cables, or terminals. Performing this procedure on high voltage circuits may result in serious injury
or death.

Note:  Use only DuraSeal splice sleeves. Other splice sleeves may not protect the splice from moisture or provide a good electrical connection.

Use DuraSeal splice sleeves to form a one-to-one splice on all types of insulation except Tefzel and coaxial. Use DuraSeal splice sleeves where there are
special requirements such as moisture sealing. Follow the instructions below in order to splice copper wire using DuraSeal splice sleeves.

Note:  You must perform the following procedures in the listed order. Repeat the procedure if any wire strands are damaged. You must obtain a
clean strip with all of the wire strands intact.

1. Open the harness by removing any tape:

*

Use a sewing seam ripper, available from sewing supply stores, in order to cut open the harness in order to avoid wire insulation damage.

*

Use the DuraSeal splice sleeves on all types of insulation except Tefzel and coaxial.

*

Do not use the crimp and DuraSeal splice sleeve to form a splice with more than 2 wires coming together.

2. Cut as little wire off the harness as possible. You may need the extra length of wire in order to change the location of a splice.

Adjust splice locations so that each splice is at least 40 mm (1.5 in) away from the other splices, harness branches, or connectors.

3. Strip the insulation: