chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 6790 > < Diagram Information and Instructions|Page 6788
Page 30
background image

5. Use a small flat-blade tool to remove TPA from the connector.

6. Use the J-38125-213 or the J-38125-556 tool to release the terminals by inserting the tool into the terminal release cavity.
7. While holding the removal tool in place, gently pull the wire out of the back of the connector. Always remember never use force when pulling a

terminal out of a connector.

8. Repair the terminal by following the Repairing Connector Terminals   See: General Electrical Diagnostic Procedures/Connector Repairs/Repairing

Connector Terminals procedure.

9. Insert the repaired terminal back into the cavity. Repeat the diagnostic procedure to verify the repair and reconnect the connector bodies.

Note:  Ensure that the dress cover and connector body are both in the released position before reassembling. Failure to do so may cause damage to
the connector and component.

10. Reconnect the connector bodies.

Delphi Connectors

Diagram Information and Instructions|Page 6790 > < Diagram Information and Instructions|Page 6788