Page 1
background image

Inflatable Restraint Sensing And Diagnostic Module: Service and Repair

INFLATABLE RESTRAINT SENSING AND DIAGNOSTIC MODULE REPLACEMENT

REMOVAL PROCEDURE

1. Disable the SIR system. Refer to SIR Disabling and Enabling Zone 1 and SIR Disabling and Enabling Zone 3.

CAUTION:
-

Do not strike or jolt the inflatable restraint sensing and diagnostic module (SDM). Before applying power to the SDM, make sure that it is
securely fastened with the arrow facing toward the front of the vehicle. Failure to observe the correct installation procedure could cause
SIR deployment, personal injury, or unnecessary SIR system repairs.

-

If the vehicle interior is exposed to moisture and becomes soaked up to the level of the sensing and diagnostic module (SDM), the SDM
and SDM harness connector must be replaced. The SDM could be activated when powered, which could cause airbag deployment and
result in personal injury.

-

Refer to SIR Caution in Service Precautions.

2. Remove the floor console, if equipped.
3. Cut an "X" in the carpet over the inflatable restraint sensing and diagnostic module (SDM).
4. Fold the carpet back to expose the SDM.

5. Remove the connector position assurance (CPA) (4) from the SDM harness connector (3).
6. Disconnect the SDM harness connector (3) from the SDM (2).
7. Remove the SDM mounting fasteners (1).
8. Remove the SDM (2) from the vehicle.
9. Repair the fasteners using the following procedure:

IMPORTANT:  The following repair procedures should only be used in the event that the inflatable restraint sensing and diagnostic module (SDM)
mounting studs and/or fasteners are damaged to the extent that the SDM may no longer be properly mounted.

9.1.

Remove the stripped nut and discard the nut.

9.2.

Drill out the weld spots to the weld stud from the floor pan side, then remove and discard the stud.

9.3.

Condition the floor panel attaching surface where the new stud is to be installed.

9.4.

Install new weld stud GM P/N 115115602 and clamp the weld stud.

9.5.

Migweld the stud at the drilled holes from above or below the floor pan (as required).

9.6.

Apply body sealer GM P/N 9984248 around any exposed openings.

9.7.

Install a new fastener GM P/N 11515933.

INSTALLATION PROCEDURE

1. Remove any dirt, grease, or other impurities from the mounting surface.

Inflatable Restraint Sensing And Diagnostic Module <--> [Air Bag Control Module]|Locations|Page 6624 > < Inflatable Restraint Sensing And Diagnostic Module <--> [Air Bag Control Module]|Locations|Page 6622