Important:  The image depicts the improper installation of the retainer ring to the connector fitting. Failure to follow the proper installation
procedure could result in cooler line separation from the connector fitting.

2. Install the retaining rings (E-clips) onto the two quick connect fittings by using the following procedures:

-

Obtain a "NEW" retaining ring for assembly.

-

Hook one of the ends of the retainer spring into one of the quick connector slots.