chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Instruments - Gauges Inoperative|Page 881 > < Campaign - HVAC Blower Not Functional Runs Continuously|Page 871
Page 1
background image

Instrument Panel Control Module: Customer Interest
Instruments - Gauges Inoperative

Bulletin No.: 03-08-49-020

Date: November 19, 2003

TECHNICAL

Subject:
Instrument Panel Cluster (IPC) Gauges Inoperative (Reprogram IPC)

Models:
2003 Cadillac Escalade, Escalade ESV, Escalade EXT
2003 Chevrolet Avalanche, Silverado, Suburban, Tahoe
2003 GMC Sierra, Yukon, Yukon XL

Condition

Some customers may comment that upon vehicle start-up, all instrument panel cluster gauges are inoperative.

Cause

During a cold start or low battery condition, a low voltage condition may cause gauges to freeze during crank cycle.

Correction

Important:

DO NOT REPLACE the following clusters unless a reprogram does not correct this condition.

^

15182138

^

15182139

^

15182140

^

15182141

^

15182142

^

15182143

^

15182144

^

15182145

^

15182146

^

15182147

^

15182148

^

15182149

^

15182150

^

15182151

^

15182152

^

15182153

^

15182154

^

15182155

^

15182156

^

15182157

^

15177467

^

15177468

A new service calibration has been released to correct this condition. Reprogram the IPC using the new service calibration, which was available from
Techline starting November 3, 2003 on the TIS2000 version 11.5 or later. This calibration is an electronic calibration and is not available from GMSPO.

Warranty Information

Instruments - Gauges Inoperative|Page 881 > < Campaign - HVAC Blower Not Functional Runs Continuously|Page 871