Accumulator HVAC: Description and Operation

OPERATION

The sealed accumulator assembly connects to the evaporator outlet pipe. It functions as a liquid/vapor separator that receives refrigerant vapor, some
liquid refrigerant and refrigerant oil from the evaporator. It only allows refrigerant vapor and oil to flow to the compressor.

At the bottom of the accumulator is desiccant that acts as a drying agent for moisture that may have entered the system. An oil bleed hole is also
located near the bottom of the accumulator outlet pipe to provide an oil return path to the compressor.

A low-side pressure service fitting is located on the accumulator. A similar service fitting is provided for mounting the cycling pressure switch. It is
not necessary to discharge the system to replace the switch. The accumulator is serviced only as a replacement assembly.