C 2500 Suburban 2WD V8-454 7.4L VIN J SFI (1998)
Refrigerant Pressure Sensor / Switch: Description and Operation
High Pressure Cut-Off Switch
High Pressure Cutoff Switch
The system is also equipped with a high pressure cutoff switch. This switch is normally closed, and opens at 2827-3103 kPa (410-450 psi) to interrupt
the voltage to the compressor clutch coil. This will stop the compressor from cycling and prevent the pressure relief valve from discharging refrigerant
and oil.