background image

Important:  Align the arrow at the throttle body end of the duct with the throttle body attaching stud.

10. Install the air cleaner outlet duct.
11. Install the radiator inlet hose clip to the outlet duct.

Notice:  Refer to Fastener Notice in Service Precautions.

12. Tighten the air cleaner outlet duct clamps at the following locations:

^

Throttle body

^

MAF/IAT sensor

^

Tighten the air cleaner outlet duct clamp screws to 7 Nm (62 inch lbs.).

13. Fill the cooling system. 