chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

A/C - Noisy/Inoperative|Page 13103 > < A/C - Noisy/Inoperative|Page 13101
Page 1
background image

Expansion Block/Orifice Tube: Service and Repair

EXPANSION (ORIFICE) TUBE REPLACEMENT

TOOLS REQUIRED

-

J 26549-E Orifice Tube Remover

-

J 39400-A Halogen Leak Detector

REMOVAL PROCEDURE

1. Recover the refrigerant. Refer to Refrigerant Recovery and Recharging.
2. Loosen the nut from the evaporator tube fitting.
3. Use the J 26549-E in order to remove the expansion (orifice) tube from the evaporator tube.
4. Cap or plug the open line.

INSTALLATION PROCEDURE

1. Uncap or unplug the evaporator tube.
2. Lubricate the new O-ring using new 525 viscosity refrigerant oil.
3. Install the new O-ring seal.
4. Install the orifice tube (1) to the evaporator tube (2).

4.1. Coat the O-ring seal with 525 viscosity refrigerant oil.
4.2. Insert the short screen end of the new orifice (1) into the evaporator tube.

NOTE:  Refer to Fastener Notice in Service Precautions.

A/C - Noisy/Inoperative|Page 13103 > < A/C - Noisy/Inoperative|Page 13101