C 2500 Truck 2WD V8-8.1L VIN G (2002)
Installation Procedure
Notice: Refer to Fastener Notice in Service Precautions.
1. If replacing the water crossover install the following:
1.1.
Thermostat (3)
1.2.
Water outlet (1)
1.3.
Water outlet bolts (2)
-
Tighten the water outlet bolts to 30 Nm (22 ft. lbs.).
2. Install NEW water crossover gaskets.
3. Install the water crossover.
4. Install the water crossover bolts.
-
Tighten the water crossover bolts to 50 Nm (37 ft. lbs.).