chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Surge Tank Hose/Pipe Replacement - Inlet|Page 4041 > < Surge Tank Hose/Pipe Replacement - Inlet|Page 4039
Page 3
background image

1. Install a new O-ring seal on the water outlet tube.
2. Lightly lubricate the O-ring seal with coolant.
3. Install the water outlet tube. 

Notice:  Refer to Fastener Notice in Service Precautions.

4. Install the bolt retaining the water outlet tube to the thermostat housing.

-

Tighten the water outlet tube to thermostat housing bolt to 21 Nm (15 ft. lbs.).

5. Install the 2 bolts retaining the water outlet tube to the valve rocker arm cover. 

-

Tighten the water outlet tube to valve rocker arm cover bolts to 21 Nm (15 ft. lbs.).

6. Install the turbocharger bypass valve and sealing washer to the water outlet tube. 

-

Tighten the turbocharger bypass valve to 60 Nm (44 ft. lbs.).

7. Connect the turbocharger coolant hose to the turbocharger bypass valve.

Surge Tank Hose/Pipe Replacement - Inlet|Page 4041 > < Surge Tank Hose/Pipe Replacement - Inlet|Page 4039