Camaro V8-350 5.7L (1989)
Oxygen Sensor: Service and Repair
The oxygen sensor has a permanently attached pig-tail and connector. This pig-tail should not be removed, since removal will affect proper operation of
the oxygen sensor.
1.
Disconnect electrical connector from oxygen sensor.
2.
Using a suitable wrench, carefully remove sensor from the exhaust manifold or pipe. The oxygen sensor may be difficult to remove when the
engine temperature is below 120°F. Use caution, since excessive force may damage threads in exhaust manifold or pipe.
3.
If a new sensor is being used, install the sensor into the manifold or pipe.
4.
If the old sensor is being reused, coat the threads with anti-seize compound, then install it into the manifold or pipe.
5.
Torque oxygen sensor to specifications, then reconnect electrical connector.