Blower Motor: Service and Repair

Remove or Disconnect

1. Key from ignition switch to assure that switch will remain OFF.
2. Right instrument panel insulator and side trim panel.
3. Blower motor bolts/screws (32).

^

Blower motor (6) and blower motor fan (18) will drop down.

Inspect
^

Blower motor terminals for corrosion. Clean corrosion from terminals or replace blower motor (6) as necessary.

^

Flange of blower motor (6) for damage or distortion that could cause an air leak. Repair as necessary.

^

Blower motor fan (18) for damage and distortion. Repair or replace as necessary.

Install or Connect

1. Blower motor (6).

^

Guide blower motor (6) and blower motor fan (18) into position, being careful not to catch blower motor fan (18) on protruding parts.

2. Blower motor bolts/screws (32).

Tighten
^

Blower motor bolts/screws (32) to 2.3 N.m (20 lb. in.).

3. Right instrument panel insulator and side trim panel.
4. Check blower operation.