chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 19 > < Diagram Information and Instructions|Page 17
Page 6
background image

When front probing of connectors is required, always use a mating terminal adapter from Connector Test Adapter Kit (J 35616-A). The use of
proper adapters will ensure that proper terminal contact integrity is maintained. (refer to Procedures in Checking Terminal Contact).

Backprobe
Only backprobe connector terminals when specifically called for in diagnostic procedures. Since backprobing can be a source of damage to
connector terminals, extra care must be taken to avoid deforming the terminal, either by forcing the test probe too far into the cavity or by using
too large a test probe.

After backprobing any connector, always check for terminal damage. If terminal damage is suspected, check for proper terminal contact, refer to 
Checking Terminal Contact.  

Testing For Voltage Front probe

Voltage Check

1. Connect one lead of a test light to a known good ground. When using a Digital Voltmeter (DVM), be sure the voltmeter's negative lead is

connected to ground.

2. Connect the other lead of the test light or voltmeter to a selected test point (connector or terminal).
3. If the test light illuminates, there is voltage present. When using a DVM, note the voltage reading.

Testing For Continuity

Continuity Check Through A Switch

1.  Remove the fuse to the circuit involved.
2.  Connect one lead of a self-powered test light or ohmmeter to one end of the part of the circuit you wish to test.
3. Connect the other lead to the other end of the circuit.
4. If the self-powered test light glows, there is continuity. When using an ohmmeter, LO or no resistance means good continuity.

Testing For Voltage Drop

Diagram Information and Instructions|Page 19 > < Diagram Information and Instructions|Page 17