chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Heated Oxygen Sensor - Bank 1 Sensor 1|Page 3761 > < Heated Oxygen Sensor - Bank 1 Sensor 1|Page 3759
Page 3
background image

Caution:  A special anti-seize compound is used on the oxygen sensor threads. New service sensors should already have the compound applied to
the threads. Coat the threads of a reused sensor with anti-seize compound P/N 5613695 or equivalent.

1. Install the HO2S (2) to the right catalytic converter and tighten to 42 Nm (31 lb ft).
2. Connect the HO2S electrical connector (1).
3. Lower the vehicle.
4. Connect the battery negative cable. Refer to Battery Negative Cable Disconnection and Connection   (See: Starting and Charging/Battery/Battery

Cable/Negative/Service and Repair/Battery Negative Cable Disconnection and Connection).

Heated Oxygen Sensor - Bank 1 Sensor 1|Page 3761 > < Heated Oxygen Sensor - Bank 1 Sensor 1|Page 3759