7. Use a hand file to round the edge of the motor mount (5) in the battery positive starter cable-to-motor mount contact area.

Caution:

To avoid battery positive starter cable damage, wrap the battery positive starter cable with the protective tapes specified in this bulletin. Do NOT use any
other tape to complete the repair.

8. Pull the conduit on the battery positive starter cable forward to the terminal and tape it in place using Elliott EG190 tape (P/N 19117900 or 19117901
to be available in the future).

1. Secure the conduit to the battery positive starter terminal with Elliott EG190 tape (P/N 19117900 or 19117901 to be available in the future).

2. Begin wrapping the tape at the terminal end of the battery positive starter cable and continue wrapping the tape 76 mm (3 in) forward toward the
front of the vehicle.

3. Wrap the Elliott EG190 tape (P/N 19117900 or 19117901 to be available in the future) around the battery positive starter cable in the specified 76
mm (3 in) section of the cable (A) four times at 50 percent overlap.

4. Wrap the other end of the conduit that is forward of the motor mount (C) with the Elliott EG190 tape (P/N 19117900 or 19117901 to be available in
the future) to secure the conduit to the channel.

9. Wrap a piece of Polyken 342 tape, P/N 10184916, around the battery positive starter cable (3) in the motor mount contact area (6) of the cable. Wrap
the tape around the cable until it is forward of the motor mount. The tape wrap area (7) should measure about 102 mm (4 in) in length. Wrap the tape in
the motor mount area 3 times at 50 percent overlap.

10. Cut a 50 mm (2 in) X 127 mm (5 in) piece of butyl patch, P/N 25757810.

11. Clean the motor mount contact area (6) with 50/50 water isopropyl alcohol solution and a shop towel.

Recall - Positive Battery Cable Routing|Page 6637 > < Recall - Positive Battery Cable Routing|Page 6635