Fuel Tank Unit: Service and Repair

Fuel Sender Assembly

REMOVAL PROCEDURE

1. Disconnect the negative battery cable.
2. Perform the Fuel Pressure Release Procedure.
3. Drain the fuel tank.
4. Remove the fuel tank.
5. Remove the fuel sender assembly:

A. Remove the fuel sender assembly retaining nuts (1), the retaining ring (2), the fuel sender assembly (3), and the gasket (4). Discard the gasket.
B. Clean the gasket sealing surfaces.

IF REPLACING THE ENTIRE UNIT PROCEED TO INSTALLATION STEP 10.   
 

6. Note the position of the fuel strainer (9) on the fuel pump (7).
7. Support the fuel sender assembly (6) with one hand and grasp the strainer (9) with the other hand.
8. Rotate the strainer in one direction and pull the strainer off the pump. Discard the strainer after inspection.
9. Inspect the strainer. Replace a contaminated strainer and clean the fuel tank.

10. Inspect the fuel pump inlet for dirt and debris.

-

If found, replace the fuel pump.

11. If the fuel pump is being replaced, proceed to Step 12.
12. Loosen the clamp (4) and remove the fuel feed hose (3) from the fuel pump outlet.
13. Remove the terminal retainer.
14. Disconnect the fuel pump electrical connector and the electrical connector from the bottom of the sender cover.
15. Remove the retainer clip (1) from the fuel return pipe.
16. Remove the fuel pump and fuel level sensor assembly and the spring (2) from the fuel sender.
17. Remove the housing cover (5) from the fuel pump housing (8).
18. Remove the fuel pump (7) from the fuel pump housing (8).

CAUTION:  Do Not run the fuel pump unless the fuel pump is submerged in fuel.

19. If the fuel level sensor is being replaced, proceed to Step 20.
20. Slide the fuel level sensor (10) from the retainers on the fuel pump housing (8).

INSTALLATION PROCEDURE

1. Install the fuel level sensor (10) to the fuel pump housing (8).
2. Install the fuel pump (7) and the isolator into the fuel pump housing (8).

Important: The small hole in the housing cover (5) aligns over the fuel level sensor (10).

3. Install the housing cover (5) to the fuel pump housing (8).

Important: The fuel pump and fuel level sensor assembly must be aligned directly under the fuel sender cover.

4. Slide the fuel pump and fuel level sensor assembly and spring (2) onto the fuel return pipe.
5. Compress the spring (2) and install the retainer clip (1) through the fuel return pipe.