Caprice RWD V8-305 5.0L (1992)
Air Door Actuator / Motor: Customer Interest
A/C - Extreme Temperature Difference in Bi-Level Mode
Number: 93-158-1B
Section: 1B
Date: MAY 1993
Corporate Bulletin No.: 23121OR
ASE No.: A7
Subject:
EXTREME TEMPERATURE DIFFERENCE IN BI-LEVEL MODE
Model and Year:
1992-93 CAPRICE
CONDITION:
Temperature difference between instrument panel vents and heater ducts (Bi-level mode) can vary by 50-60 degrees Fahrenheit.
CAUSE:
The heater shutoff air door is not in the correct stop position. Air is not allowed to mix to the approximate 25 degree Fahrenheit difference intended for
this system.
CORRECTION:
By installing a screw as a stop in the inner case wall, the heater shutoff door will park in the correct position, allowing a better mixture of air.
The repair procedure is as follows: