Expansion Block/Orifice Tube > < Blower Motor and Evaporator|Page 8813
Page 4
background image

6. Moisture drain tube to the HVAC module.
7. Evaporator fittings to evaporator using new O-ring seals lubricated in clean 525 viscosity refrigerant oil.

Tighten
^

Fittings to 24 Nm (18 lb ft).

8. Heater hoses to heater core.
9. Lower vehicle.

10. Fill cooling system and check for leaks.
11. Evacuate and charge the A/C system. 
12. Negative battery cable.

Tighten
^

Bolt to 16 Nm (12 lb ft).