REMOVAL PROCEDURE
1. Remove the console.
2. Remove the closeout cover from the air outlet.
3. Reposition the floor carpet aside in order to access the floor outlet duct connections.
4. Remove the floor outlet ducts from the heater outlet cover.
5. Remove the floor outlet ducts.
INSTALLATION PROCEDURE
1. Install the floor outlet ducts to the heater outlet cover.
2. Install the floor outlet ducts over the stud and slide them into position.
3. Position the carpet back into place.
4. Install the closeout cover to the air outlet.
5. Install the closeout cover bolts to the air outlet.
Tighten
Tighten the bolts to 2.3 N.m (20 lb in).
6. Install the console.