Cavalier Z24 1995 Audible Warning Device Description and Operation
Audible Warning Device: Description and Operation
Fasten Belts Chime
With the Ignition Switch in "RUN," "BULB TEST" or "START," voltage is applied through the ALARM Fuse to Conn C1 term "M" of the
Multi-function Alarm Module. With the LH front seat belt unbuckled, Conn C1 term "K" of the Multi-function Alarm Module is grounded through the
Seat Belt Switch. The fasten belts chime sounds for 4 to 8 seconds.