Audible Warning Device: Description and Operation
Key-In-Ignition Chime

Voltage is applied at all times to Conn C2 term "D" of the Multi-Function Alarm Module through the INT LAMP Fuse. When the key is in the ignition
and LH front door is open, Conn C1 term "H" and term "E" of the Multi-Function Alarm Module are grounded. This sounds the chime.