Citation V6-173 2.8L VIN Z 2-bbl HP (1983)
FIGURE 3 - HOUSING REFERENCE MARK (TYPICAL)ANDRACK CENTERING MEASUREMENT
Inspect
When pinion and valve assembly is fully seated, flat or notch in stub shaft and mark on housing must line up while the rack is centered in the
housing. Refer to measurement "A" to verify proper rack position. (See Figure 3.)
7.
While holding the stub shaft, thread lock nut onto pinion and torque to 35 N-m (26 Ft.Lbs.).
vImportant
If the stub is not held, damage to the pinion teeth will occur.