Cobalt L4-2.0L SC VIN P (2005)
2. Remove the outer air duct screw and duct.
INSTALLATION PROCEDURE
1. Install the outer air duct.
2. Install the outer air duct screw.
NOTE: Refer to Fastener Notice in Service Precautions.
Tighten the air outlet duct screw to 2.5 N.m (22 lb in).
3. Install the right instrument panel (I/P) trim panel.