6. Remove and discard the seal washers.

INSTALLATION PROCEDURE

1. Install new sealing washers on the condenser tube and evaporator hose fittings.
2. Install the condenser tube and evaporator hose to the TXV.
3. Install the TXV nut.

NOTE:  Refer to Fastener Notice in Service Precautions.

Tighten the nut to 20 N.m (15 lb ft).

4. Install the new seal washer to the compressor hose.
5. Install the compressor hose and nut to the evaporator hose.

Tighten the nut to 20 N.m (15 lb ft).

6. Install the retainer clamp to the evaporator hose.
7. Evacuate and charge the refrigerant system. Refer to Refrigerant Recovery and Recharging.
8. Leak test the fittings using the J 39400-A.

Radiator Hose > < Condenser Tube|Page 2925