chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Evaporative Emissions System > < Exhaust System - Catalytic Converter Precautions|Page 7089
Page 2
background image

1. Install NEW exhaust gaskets to the exhaust manifold and to the exhaust extension pipe. The gaskets are designed to be retained to the flange by the

flange studs.

2. Position the catalytic converter pipe assembly to the vehicle.
3. Move the extension pipe rearward and down in order to connect the converter pipe to the extension pipe.

4. Notice:  Refer to Fastener Notice in Service Precautions.

Install the catalytic converter pipe-to-exhaust extension pipe nuts.
^

Tighten the nuts to 30 Nm (22 ft. lbs.).

5. Carefully install the converter pipe to the exhaust manifold.

6. Install the catalytic converter pipe-to-exhaust manifold nuts.

^

Tighten the nuts to 50 Nm (37 ft. lbs.).

7. Install the post catalytic converter HO2S. 
8. Lower the vehicle.