Crankshaft Balancer Replacement
Tools Required
*
J 38122-A Harmonic Balancer Holder
*
J 45059 Angle Meter
Removal Procedure
1. Remove the drive belt.
2. Use J 38122-A to prevent the crankshaft from rotating while loosening the crankshaft balancer bolt.
3. Remove and discard the crankshaft balancer bolt.
4. Remove the crankshaft balancer.
Installation Procedure