chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Air Door Cable, HVAC > < Air Door Actuator / Motor, HVAC|Locations|Page 13101
Page 1
background image

Air Door Actuator / Motor: Service and Repair

Recirculation Actuator Replacement

Removal Procedure

1. Remove the HVAC module assembly.

2. Remove the recirculation actuator screws.
3. Remove the electrical connector (3) from the recirculation actuator (2).
4. Remove the recirculation actuator.

Installation Procedure

1. Install the recirculation actuator (2).

Notice:  Refer to Fastener Notice.

2. Install the screws to the recirculation actuator.

Tighten the screws to 1.9 N.m (17 lb ft).

3. Connect the electrical connector (3) to the recirculation actuator (2).
4. Install the HVAC module assembly.

Air Door Cable, HVAC > < Air Door Actuator / Motor, HVAC|Locations|Page 13101