Refrigerant Pressure Sensor / Switch: Service and Repair

Air Conditioning (A/C) Refrigerant Pressure Sensor Replacement

Tools Required

J39400-A Halogen Leak Detector

Removal Procedure

1. Disconnect the A/C refrigerant pressure sensor electrical connector.
2. Remove the A/C refrigerant pressure sensor from the evaporator inlet tube.

Installation Procedure

1. Using a lint-free clean, dry cloth, carefully clean the sealing surfaces of the evaporator inlet tube fitting.

Important:  DO NOT allow any of the mineral base 525 viscosity refrigerant oil on the O-ring seal to enter the refrigerant system.

2. Lightly coat the O-ring seal with mineral base 525 viscosity refrigerant oil.

Notice:  Refer to Fastener Notice.

3. Install the A/C refrigerant pressure sensor to the evaporator inlet tube.

Tighten the sensor to 5 N.m (44 lb in).

4. Connect the A/C refrigerant pressure sensor electrical connector.