Corsica L4-121 2.0L (1988)
Blower Motor: Initial Inspection and Diagnostic Overview
With Air Conditioning
NOTE: For a guide to normal operation go to the A/C System Check. See: Testing and Inspection
1. Check Fuse 8 by visual inspection.
2. Check that ground G101 is clean and tight.
3. Check that the Blower Motor and A/C Blower Relay connectors are mated correctly and firmly seated.
System Check
System Check Table
NOTE: Refer to the Symptom Table when a result is other thant normal.
Troubleshooting Hints
NOTE: Go to System Check for a guide to normal operation. See: Without Air Conditioning/System Check
1. If the Blower Motor does not operate at all, check fuse 8 by visual inspection.
2. If the Blower Motor does not operate at all, check that ground G101 is clean and tight.
3. If the Blower Motor does not turn off, install a new Blower Switch.