chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 8108 > < Diagram Information and Instructions|Page 8106
Page 22
background image

Wire Size Conversion Table

Step 3: Strip the Insulation
When replacing a wire, use a wire of the same size as the original wire or larger. The schematics list wire size in metric units. The table shows the
commercial (AWG) wire sizes that can be used to replace each metric wire size. Each AWG size is either equal to or larger than the equivalent
metric size.

To find the correct wire size either find the wire on the schematic Diagram and convert the metric size to the AWG size, or use an AWG wire
gage.

If you aren't sure of the wire size, start with the largest opening in the wire stripper and work down until a clean strip of the insulation is removed.
Be careful to avoid nicking or cutting any of the wires.

Centering The Splice Clip

Step 4: Crimp the Wire.
Select the proper clip to secure the splice. To determine the proper clip size for the wire being spliced, follow the directions included in the J
38125-A Terminal Repair Kit Select the correct anvil on the crimpers (On most crimpers your choice is limited to either a small or large anvil.)
Overlap the stripped wire ends and hold them between your thumb and forefinger as shown. Then, center the splice clip under the stripped wires
and hold it in place.
^

Open the crimping tool to its full width and rest one handle on a firm flat surface.

Diagram Information and Instructions|Page 8108 > < Diagram Information and Instructions|Page 8106