Corvette V8-5.7L VIN G (1997)
Refrigerant Pressure Sensor / Switch: Service and Repair
REMOVAL PROCEDURE
1. Disconnect the electrical connector.
2. Remove the sensor (1) from the evaporator tube (3).
INSTALLATION PROCEDURE
IMPORTANT: Coat the new O-ring with clean 525 refrigerant oil prior to assembly.
1. Install the sensor (1) onto evaporator tube (3).
-
Tighten the refrigerant pressure sensor (1) to 4.75 N.m (42 lb. in).
NOTICE: Refer to Fastener Notice in Service Precautions.
2. Connect the electrical connector.