chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 5993 > < Diagram Information and Instructions|Page 5991
Page 4
background image

3. Replace the fuse.

^

If the fuse blows, the short is in the wiring leading to the first connector or switch. Use a test light or DMM as described on previous page.

^

If fuse does not blow, refer to next step. 

Close each connector or switch until the fuse blows in order to find which circuit has the short. Connect test light or DMM at the connector to the
suspect circuit (disconnected) rather than at the fuse terminals.

Testing For Voltage

Connect one lead of a test light to a known good ground. When using a Digital Multimeter (DMM), be sure the voltmeter's negative lead is connected to
ground.

Connect the other lead of the test light or voltmeter to a selected test point (connector or terminal).

If the test light illuminates, there is voltage present. When using a DMM, note the voltage reading. 

Testing For Voltage Drop

This test checks for voltage being lost along a wire, or through a connection or switch.
Connect the positive lead of a Digital Multimeter (DMM) to the end of the wire (or to one side of the connection or switch) which is closer to the
Battery.

Connect the negative lead to the other end of the wire (or the other side of the connection or switch).

Operate the circuit.

The DMM will show the difference in voltage between the two points.

Test Light

A test light is a simple quick way to check a circuit for voltage. The J 34142-B test light is made up of a 12 volt light bulb with a pair of leads attached.
After grounding one lead, touch the other lead to various points along the circuit where voltage should be present. When the bulb goes on, there is
voltage at the point being tested. A J 21008-A self-powered test light can be used to check for continuity. This tool is made up of a light bulb, Battery
and two leads. If the leads are touched together, the bulb will go on. A self-powered test light is used only on an unpowered circuit. First remove the fuse
which feeds the circuit you're working on. Select two specific points along the circuit through which there should be continuity. Connect one lead of the
self-powered test light to each point. If there is continuity, the test light circuit will be completed and the bulb will go on. Never use a self-powered test
light on circuits that contain solid state components, since damage to these components may result.

Digital Multimeter (DMM)

A Digital Multimeter (DMM) can be used instead of a test light to check for voltage. While a test light shows whether or not voltage is present, a DMM
indicates how much voltage is present.

An increasing number of circuits include solid-state control modules. One example is the Powertrain Control Module (PCM). Voltages in these circuits
should be tested only with a 10-megohm or higher impedance J 39200 Digital Multimeter (DMM). Unless directed to within the diagnostics, never use a
test light on circuits that contain solid state components, since damage to these components may result. 

When testing for voltage or continuity at the connection, it is not necessary to separate the two halves of the connector. Unless testing a Weather Pack(R)
or a Metri Pack(R) connector 150 series and below, always probe the connector from the back. Always check both sides of the connector. An
accumulation of dirt and corrosion between contact surfaces is sometimes a cause of electrical problems. A terminal contact checking procedure can be
found later.

A Digital Multimeter can also be used instead of a self-powered test light to check for circuit continuity. The ohmmeter function on a DMM shows how
much resistance there is between two points along a circuit. Low resistance means good continuity. 

Circuits which include any solid state control modules, such as the PCM, should be tested only with a 10-megohm or higher impedance J 39200 digital
Multimeter.

When measuring resistance with a DMM, the vehicle's Battery should be disconnected. This will prevent incorrect readings. DMMs apply such a small
voltage to measure resistance that the presence of voltages can upset a resistance reading.

Diodes and solid state components in a circuit can cause an Digital Multimeter to give a false reading. To find out if a component is affecting a
measurement, take a reading once, reverse the leads and take a second reading. If the readings differ, the solid state component is affecting the
measurement.

Connector Test Adapters

Connector Test Adapter Kit is available for making tests and measurements at separated connectors. This kit contains an assortment of probes which
mate with many of the types of terminals you will see. Avoid using paper clips and other substitutes since they can damage terminals and cause incorrect
measurements.

Fused Jumper Wire

The J 36169 fused jumper is available with small clamp connectors providing adaptation to most connectors without damage. This fused jumper wire is
supplied with a 20 A fuse which may not be suitable for some circuits. Do not use a fuse with a higher rating than the fuse that protects the circuit being

Diagram Information and Instructions|Page 5993 > < Diagram Information and Instructions|Page 5991