Corvette V8-5.7L VIN G (1997)
3. Connect the inflatable restraint front end discriminating sensor harness connector to the sensor.
4. Install the Connector Position Assurance (CPA) to the inflatable restraint front end discriminating sensor harness connector.
5. Install the Air Cleaner Assembly.
6. Enable the SIR system. Refer to Air Bag(s) Arming and Disarming.
TIGHTEN
Sensor Fastener to 10 N.m (89 lb. in).