Pedal Positioning Sensor: Service and Repair
Brake Pedal Position Sensor Calibration

BRAKE PEDAL POSITION SENSOR CALIBRATION

CALIBRATION CRITERIA

Brake pedal position sensor calibration must be performed after the brake pedal position sensor or electronic brake control module (EBCM) have been
serviced. The calibration procedure will set brake pedal position sensor home value. This value is used by the EBCM to determine the action of the
driver applying the brake system and to provide this information to the vehicle subsystems via the class 2 communication bus.

IMPORTANT:  Do not apply the brake pedal during the brake pedal position sensor calibration procedure. Any movement of the brake pedal during
this procedure will cause the calibration procedure to fail. If this occurs, the brake pedal position sensor calibration must be repeated.

CALIBRATION PROCEDURE

1. Apply the parking brake.
2. Place the transmission is in the PARK position.
3. Install a scan tool.
4. Clear all BCM DTCs before proceeding.
5. Turn ON the ignition, with the engine OFF.
6. Navigate to the Vehicle Control System menu.
7. Select Computer/Integrating Systems menu item.
8. Select Module Replacement/Setup menu item.
9. Select BCM menu item.

10. Select the BPPS calibration procedure and follow the directions displayed on the screen.

Brake Pedal Position Sensor Calibration|Page 10483 > < Pedal Positioning Sensor|Diagrams