Corvette V8-6.0L VIN U (2005)
Air Door Actuator / Motor: Service and Repair
Recirculation Actuator
RECIRCULATION ACTUATOR REPLACEMENT
REMOVAL PROCEDURE
1. Remove the RH lower insulator panel.
2. Disconnect the HVAC module wiring harness from the recirculation housing wire harness retainer.
3. Remove the recirculation actuator mounting screws.
4. Remove the recirculation actuator.
5. Disconnect the electrical connector from the recirculation actuator.
INSTALLATION PROCEDURE
1. Connect the recirculation actuator electrical connector.