Page 2
background image

6. Disconnect the discharge temperature management (DTM) sensor electrical connectors.
7. Disconnect the HVAC module wiring harness retainer pin (2) from the HVAC module.
8. Disconnect the wiring harness from the heater core cover wire harness retainer (1) and reposition the wiring harness aside.
9. Disconnect the wiring harness from the heater core cover wire harness retainer (3) and reposition the wiring harness aside.

10. Remove the heater cover screws.
11. Remove the heater cover from the HVAC module.