2. Install the water pump bolts.

1. Tighten the water pump bolts a first pass to 15 N.m (11 lb ft).
2. Tighten the water pump bolts a final pass to 30 N.m (22 lb ft).

3. Install the heater inlet and surge tank outlet hoses to the water pump.
4. Position the heater inlet and surge tank outlet hose clamps at the water pump.

5. Install the inlet and outlet hoses to the water pump.
6. Position the inlet and outlet hose clamps at the water pump.
7. Install the accessory drive belt.
8. Fill the cooling system. Refer to Draining and Filling Cooling System (GE 47716) Draining and Filling Cooling System (Static Fill).

9. Install the air cleaner intake duct.