chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Housing Assembly HVAC|Service and Repair|Page 15263 > < A/C Line/Tube Connector Removal/Replacement|Page 15259
Page 1
background image

Housing Assembly HVAC: Service and Repair

HVAC MODULE ASSEMBLY REPLACEMENT

TOOLS REQUIRED

J 39400-A Halogen Leak Detector

REMOVAL PROCEDURE

1. Recover the refrigerant from the A/C system. Refer to Refrigerant Recovery and Recharging.
2. Drain the cooling system. Refer to Draining and Filling Cooling System in Cooling System.
3. Remove the heater pipe assembly.

4. Remove the evaporator drain tube (1) from the HVAC module.
5. Remove the instrument panel (I/P) assembly.