Instrument Panel Control Module: Customer Interest
Instruments - Gauges Inoperative/Erratic/Inaccurate

TECHNICAL

Bulletin No.: 08-08-49-017B

Date: April 20, 2009

Subject: 

Instrument Panel Cluster (IPC) Gages Inoperative, Erratic/Inaccurate Gauge Readings (Reprogram IPC)

Models:

2008 Buick Enclave
2008 Chevrolet Equinox, HHR, Malibu (excluding Malibu Classic)
2008 GMC Acadia
2008 Pontiac Torrent
2008 Saturn AURA, OUTLOOK

Supercede:
This bulletin is being revised to include the HHR models. Please discard Corporate Bulletin Number 08-08-49-017A (Section 08 - Body and
Accessories).

Condition

Some customers may comment that the instrument gages appear to be erratic/inaccurate or are inoperative.

This condition may be intermittent and occur over one or multiple ignition cycles, eventually resetting itself.

Cause

A software anomaly within the IPC allows the microprocessor to lose communication with the gage temporarily.

Correction

A revised calibration has been developed to correct this condition. Technicians are to reprogram the instrument panel cluster (IPC) using SPS with the
latest software available on TIS2WEB. Refer to the Service Programming System (SPS) procedures in SI. As always make sure your Tech 2(R) is
updated with the latest software version. 

Warranty Information

For vehicles repaired under warranty, use the table above.