Express 1/2 Ton Van V6-4.3L VIN W (1999)
Starter Motor Noise Diagnosis
Starter No Load Test (28-MT)
TOOLS REQUIRED:
-
J 39200 Digital Multimeter
-
J 35590 Current Clamp
1. Connect a voltmeter from the motor terminal to the motor frame.
On starter motors with ground terminals, connect the voltmeter to the ground terminals rather than the frame.