Heated Oxygen Sensor: Testing and Inspection

Heated Oxygen Sensor (HO2S) Cutaway

The Heated Oxygen Sensors are mounted in the exhaust system where they can monitor the oxygen content of the exhaust gas stream. The oxygen
present in the exhaust gas reacts with the sensor to produce a voltage output. This voltage should constantly fluctuate from approximately 100 mV
(high oxygen content - lean mixture) to 900 mV (low oxygen content - rich mixture). The heated oxygen sensor voltage can be monitored with a scan
tool. By monitoring the voltage output of the oxygen sensor, the VCM calculates what fuel mixture command to give to the injectors (lean mixture -
low HO2S voltage = rich command, rich mixture - high HO2S voltage = lean command).

When the VCM detects an HO2S signal circuit that is low, the VCM will set the following DTCs:

^

DTC P0131 Bank 1 Sensor 1 HO2S